VTech Solution · Sahibabad, Ghaziabad · Authorised Jotun & Graco Distributor Call +91 98111 70042 sales@vtechsolution.co.in

Airless Spraying of Intumescent Fire Proof Paint on Structural Steel

Airless Spraying of Intumescent Fire Proof Paint on Structural Steel

Why is airless spraying used for intumescent fire proof paint?

Intumescent coatings are thick, high-solids materials applied to a specified dry film thickness on structural steel. Airless spraying pushes this heavy material through a small tip at high pressure, giving fast coverage, even build and fewer coats than a brush or roller. Always follow the coating data sheet and the Graco manual.

Steel loses strength quickly in a fire. Intumescent paint is a passive fire protection coating that swells into an insulating char when heated, which buys time for people to leave and for firefighters to work. On a large warehouse, factory or multi-storey frame, applying this material by brush or roller is slow and the thickness is hard to keep even. That is why contractors across Delhi NCR increasingly ask about airless spraying for intumescent coatings.

This guide is general guidance for contractors, fabricators and site engineers. It explains why airless suits these coatings, how to plan thickness and coats, what to check on the spray equipment, and how inspection works. The coating data sheet and the fire protection specification for your project always decide the final method. Treat this article as a planning aid and not as a substitute for either.

What intumescent paint does on structural steel

Unprotected structural steel starts to lose strength at temperatures that a building fire reaches in minutes. Intumescent paint sits on the steel like a thick coating in normal service. In a fire, it expands and forms a foamy, insulating layer that slows the heat reaching the steel. The result is extra time, measured in the fire rating your consultant specifies for each member.

The fire rating is achieved only when the dry film thickness (DFT) matches the approved schedule for that section size and exposure. Too thin and the rating is not met. Too thick wastes costly material and can crack or sag. This is the main reason application method matters so much.

Jotun families you may see on specifications

As a Jotun distributor and dealer, VTech Solution is often asked about Jotun Steelmaster and Jotachar. These are product families for passive fire protection of steel. Which specific product suits your project depends on the fire rating, the section factor of the steel, interior or exterior exposure, and the approved system in your specification. Check the current data sheet for the exact product, the primer it needs, the spraying guidance and the topcoat options. VTech confirms the matching product and availability when you call. See our industrial solutions and protective coatings pages for the wider range.

Why airless spraying suits intumescent coatings

Intumescent materials are heavy-bodied and applied in high film builds. Several practical reasons make airless the usual choice.

  • Fluid delivery. An airless pump develops high fluid pressure without needing atomising air. That helps move thick material through the hose and tip steadily.
  • Speed. A sprayer can cover large beams, columns and purlins far faster than a brush crew, which matters on shutdown schedules.
  • Consistency. A trained operator with a steady stroke lays a more even wet film than manual application, which makes thickness control easier.
  • Fewer passes. Higher output means a thicker wet film per pass, so the total number of coats and the repaint intervals can drop, within the limits on the data sheet.
  • Less overspray than air spray. Airless produces less bounce-back than conventional air spray, though masking and protection are still needed.

Not every intumescent product is sprayed. Some are water-based, some solvent-based, and some are two-pack. Each has its own recommended pump ratio, tip range, hose size and thinning limits. Read the data sheet and then match the equipment.

Matching the Graco sprayer to the job

Heavy coatings need a sprayer with enough flow and pressure, and a robust pump. VTech Solution is an authorised Graco distributor, and several models are relevant for protective and fire proof coating work. Final model selection depends on the material, the hose length and the crew size, which we discuss on the call.

Graco model Useful fact Where it may fit
Ultra Max II 490 Max 228 bar, up to 2.0 L/min Smaller steel packages and touch-up zones
Ultra Max II 695 Up to 2.8 L/min, 227 bar / 3300 psi Larger structural steel jobs that need higher flow
GMAX II 3900 Up to 4.73 L/min, 228 bar, up to two guns Bigger sheds and plants with a two-gun crew
GMAX II 5900 Up to 6.06 L/min, endurance piston pump High-volume protective coating work
3900 Express/HD petrol Petrol-engine airless sprayer Sites where mains power is unreliable or unavailable

Whether a particular model handles a particular intumescent product depends on the product viscosity and the recommended tip. Do not assume. Send us the product name and we will check it against the sprayer range. Browse the Graco airless sprayers page for the full range.

Surface preparation and primer first

An intumescent coating is only as good as the surface under it. Most systems need blasted or properly prepared steel, a compatible primer, and sometimes a specific primer thickness. Typical points to confirm on the data sheet:

  • The approved primer and its maximum dry film thickness.
  • The overcoating interval between primer and intumescent coat.
  • Whether a sealer or topcoat is required for the exposure.

In Delhi NCR, winter smog and fine dust settle on primed steel overnight. Wipe or blow clean before the next coat and do not spray over a dusty surface. In monsoon, check that steel temperature stays safely above the dew point or the data sheet limit, because condensation on cold steel in the early morning can ruin adhesion.

Planning thickness and coats

Thickness is the heart of the job. The fire protection schedule gives a required DFT for each steel section. The wet film applied must be higher than that to allow for the solids content, which is on the data sheet as volume solids. A simple planning relationship used in the industry is:

  • Wet film thickness equals dry film thickness divided by volume solids fraction.
  • Theoretical coverage depends on the volume solids and the target DFT.
  • Real consumption is always higher because of loss in the hose, overspray, uneven steel shapes and wastage.

Estimate quantity with the supplier using the schedule and add a realistic loss allowance. Do not size the order only from theory. For tall, open steel in wind, loss can be much larger than in a closed bay.

Multiple coats

Most intumescent systems are built in more than one coat. There is a maximum thickness per pass because a very thick wet film can sag, run or trap solvent. Typical points to plan:

  • Apply each coat in even, overlapping passes at a steady distance and speed.
  • Respect the minimum and maximum recoat interval on the data sheet.
  • Measure DFT between coats so you know how much build remains.
  • Allow full cure before topcoating or handling.

Tip selection and pressure

Airless tip choice sets the fan width and the flow rate. For heavy coatings, larger orifice sizes are usual, but the correct size and fan angle come from the data sheet and your coating supplier, not from a general rule. Use the lowest pressure that gives a clean pattern with no tails, because excess pressure increases overspray and wear. If your pattern shows tails or heavy edges, stop and fix the cause before continuing.

Equipment setup for heavy coatings

  • Hose. Use the hose diameter and length recommended in the Graco manual. Long, narrow hose loses pressure with thick material.
  • Filters. Filters help block particles but a coating with large fillers may need the filter removed or a coarse mesh used, as the data sheet advises. A blocked filter on a thick material starves the tip.
  • Mixing. Two-pack products must be mixed in the right ratio and used within the pot life. Mix only what the crew can spray in that window, especially at 45 degrees C summer temperatures when pot life shortens.
  • Flushing. Flush with the solvent or water recommended for that product straight after use. Dried intumescent in a pump is a costly mistake.

Application technique that protects thickness

Good operators follow a few habits that make DFT predictable.

  1. Spray a test panel or an offcut first to confirm pattern and wet film.
  2. Hold the gun square to the surface and a steady distance away.
  3. Trigger off the surface, not on it, and overlap each pass by about half the fan.
  4. Coat edges, flanges and web corners first, then the broad faces.
  5. Use a wet film gauge as you go so thickness is checked while you can still correct it.

Beams with flanges and webs need attention to all faces. Coat the underside of the top flange and the inside corners so thickness is even around the section.

Inspection and records

Inspection is how you prove that the fire rating has been achieved. Typical elements of an inspection plan, subject to your specification and the third-party requirements:

Stage What is checked Typical tool
Before priming Surface cleanliness and profile Visual standards, profile gauge
After primer Primer DFT and condition Dry film thickness gauge
During spraying Wet film, ambient and steel temperature, humidity Wet film comb, thermometer, hygrometer
After each coat Dry film thickness, defects, sags, voids DFT gauge, visual check
Final Total DFT against the schedule, topcoat if required DFT gauge, inspection report

Keep a log per member: location, section, required DFT, readings and date. If a reading is low, add material in the permitted way and re-check. If a reading is high, follow the product guidance because excess thickness can also cause cracking.

Common mistakes on intumescent jobs

  • Ordering material from theoretical coverage only, then running short mid-job.
  • Missing the recoat window because of rain or a power cut.
  • Using a worn tip, which gives uneven thickness.

Working conditions in Delhi NCR

Summer heat above 45 degrees C shortens pot life and makes steel surfaces very hot. Plan spraying for early morning or evening and check surface temperature limits on the data sheet. Monsoon humidity brings condensation, so check dew point before every session. Winter smog and dust demand clean surfaces between coats. In industrial belts such as Sahibabad, Loni, Noida, Manesar and Faridabad, power cuts are common, so a petrol-driven option such as the 3900 Express/HD can keep a schedule alive when the mains fails. Safety matters too: brief the crew on high-pressure and solvent risks before spraying starts.

What to tell us when you call

  • The intumescent product name, or the specification clause that names it.
  • Required fire rating and target DFT per member group.
  • Total steel area, or total tonnage with section sizes.
  • Site location, indoor or outdoor, and the access method (scaffold, scissor lift).
  • Power supply available, and whether a petrol sprayer is preferred.
  • Crew size and whether you need one or two guns.
  • Hose length from the sprayer to the farthest point of work.
  • Start date and the shutdown or handover deadline.

With these details we can suggest a suitable Graco model, confirm the Jotun family against its data sheet, and plan material quantities. Prices are quoted on the call, and warranty depends on the model and is confirmed when quoting.

Talk to VTech Solution

VTech Solution has served the Sahibabad Industrial Area and Delhi NCR since 2011 as an authorised Jotun distributor and dealer and an authorised Graco distributor. If you have a fire proofing job coming up, call us on +91 98111 70042 (Monday to Saturday, 10am to 6pm IST) or write to sales@vtechsolution.co.in. You can also use our contact page.

Frequently asked questions

Can intumescent fire proof paint be sprayed with an airless sprayer?

Many intumescent products are designed for airless spraying, because they are thick and applied at high film builds. The exact pump, hose and tip depend on the product. Check the coating data sheet for its spraying guidance and the Graco manual before choosing equipment.

Why does dry film thickness matter so much for fire proof paint?

The fire rating is reached only when the dry film thickness matches the approved schedule for each steel section. Too thin gives less protection time, and too thick can crack or sag. Measure DFT with a gauge after every coat and record readings per member.

How many coats does intumescent paint usually need?

Most systems are built in several coats because there is a maximum safe thickness per pass. The number depends on the product, required fire rating and steel section. The data sheet and your fire protection specification give the build and recoat intervals to follow.

Which Jotun families are used for steel fire protection?

Jotun Steelmaster and Jotachar are product families used for passive fire protection of structural steel. Which product suits a project depends on rating, steel section and exposure. Confirm the choice against the current data sheet; VTech Solution can help on the call.

Which Graco airless sprayer suits intumescent work?

It depends on the product and job size. Models such as Ultra Max II 695, GMAX II 3900 or GMAX II 5900 give higher flow for larger steel jobs, while a petrol 3900 Express/HD helps where power is unreliable. Send us the product and we will match it.